Reduced the CLF power incident on the CLF PD to a nominal 5µW. The CLF waveplate was adjusted, so the that CLF ISS drive offset stayed near 2.7V. This required the following changes:
| channel | new | old |
|---|---|---|
| H1:SQZ-CLF_ISS_SETPOINT | 0.130 | 0.510 |
| H1:SQZ-CLF_ISS_GAIN | 26 | 7 |
| H1:SQZ-CLF_SERVO_IN2GAIN | +16 | –4 |
| H1:SQZ-OPO_IR_RESONANCE_CLF_NOM | 0.005 | 0.05 |
| H1:SQZ-LO_SERVO_IN1GAIN | +8 | –5 |
The CLF ugf was measured to be 2.2kHz, the CLF ISS ugf is 10kHz, and the LO ugf is 4kHz.