New ENV_STAT guardian node
TJ, Dave:
TJ started a new guardian node this morning, which generated a new GRD INI file. I restarted the DAQ and h1edc to add the 23 new channels to the DAQ.
CDS Hardware monitor IOC started
Dave:
I have created a new EPICS IOC which monitors the front end hardware status. The HW status was added to the bottom of the CDS Overview MEDM, next to the DAQ block. Currently it scans all the ADC and DAC cards.
Issues with dmtviewer containers on FOM machines
Dave:
Today after rebooting the FOM Nuc computers I found a new issue with our debian-8 singularity dmtviewers, which were not accepting xml files which were not on the local disk drive. I'll investigate this further, but for now I've made a copy of the xml files in /home/controls to get the FOMs active again.
Tested NCAL status on CDS Overview.
When Timesh activated the EX NCAL this morning, I verified that the NCAL status on the CDS Overview screen did go red.