Displaying report 1-1 of 1.
Reports until 19:41, Thursday 28 November 2019
H1 General
camilla.compton@LIGO.ORG - posted 19:41, Thursday 28 November 2019 - last comment - 21:38, Thursday 28 November 2019(53556)
H1 Lockloss
Comments related to this report
camilla.compton@LIGO.ORG - 20:56, Thursday 28 November 2019 (53557)
  • 03:45 Lockloss #4 at RESONANCE
  • 03:50 Message "IR not found" but then it quickly continued and locked DRMI, maybe I should have been quicker and stopped it to manually adjust IR alignment here?
  • 03:56 Lockloss #5 at SHUTTER_ALS. Just before this lockloss can see ASC_DHARD channels have a strange change in them just before lockloss (photo: lockloss5)
  • 04:08 Lockloss #6 at DARM_TO_RF
    • This time I try to get better IR flashes, adjust COMM and DIFF but still struggle to get consistent DIFF signal.
  • 04:30 Lockloss #7 at CARM_OFFSET_REDUCTION. The ASC_DHARD channels have the same signal as in lockloss 5 (photo: lckloss7). Addionaly, the SUS ETMX UIM/L1 outputs that Jeff adjusted (alog 53540) got up to 140,000 before this lockloss (photo: lockloss7) so if we loose lock aagin I think I will try revetring these changes.
  • 04:34 Started inital alignment
    • INITAL_ALIGN got again stuck at OFFLOADING_GRREN_WFS so I again manually took ALS_X/YARM to UNLOCKED (as worked in alog 53552)
Images attached to this comment
camilla.compton@LIGO.ORG - 21:30, Thursday 28 November 2019 (53558)
  • 05:26 NLN and OBSERVING!!
edmond.merilh@LIGO.ORG - 21:38, Thursday 28 November 2019 (53559)

Good job! And... thank you!

Displaying report 1-1 of 1.