13:03 IA completed with no intervention
13:04 Attempt #1
	- Lockloss at ACQUIRE_DRMI_1F
13:15 Attempt #2
	- Lockloss at ACQUIRE_DRMI_1F
13:33 Attempt #3
13:36 Attempt #4
	- Lockloss at ACQUIRE_DRMI_1F
13:43 Attempt #5
	- Going to manual MICH_FRINGES and PRMI
	
		- Flashing looks ok to me
- PRMI Successful
- DRMI locked successfully
 
- Lockloss at CARM_OFSET_REDUCTION
14:08 Attempt #6
	- Lockloss at ACQUIRE_DRMI_1F
14:23 Attempt #7
14:56 NLN
15:00 H1 Observing
			
			
		
		 
		
		
I accepted SDF Diffs regarding te SEI_CONF state that H1 is currently in due to excessively high uSeism (see figures below)