Reports until 18:33, Wednesday 04 December 2019
H1 SEI
patrick.thomas@LIGO.ORG - posted 18:33, Wednesday 04 December 2019 - last comment - 19:03, Wednesday 04 December 2019(53691)
SEI_CONF guardian error
02:24 UTC Set SEI_CONF to EARTH_QUAKE for 5.6 mag earthquake in Japan. The SEI_CONF guardian reported a user code error (see attached). I do not know if it transitioned.
Images attached to this report
Comments related to this report
patrick.thomas@LIGO.ORG - 18:50, Wednesday 04 December 2019 (53692)
The error does not go away when I request to go back to WINDY or reload the code. I am unable to go back to observing while it persists. I have left a message on Jim's cell phone and am looking at the code.
patrick.thomas@LIGO.ORG - 19:03, Wednesday 04 December 2019 (53693)
02:56 UTC Fixed, back to observing.

I found the relevant code in /opt/rtcds/userapps/release/isi/h1/guardian/sei_config/manager.py. I ran an svn diff on it and found uncommitted changes that looked like they could be causing the problem. I copied manager.py to manager.py.backup and ran svn revert on manager.py. I then reloaded the code from the guardian screen. The error went away and I was able to go back to observing.