Displaying report 1-1 of 1.
Reports until 08:10, Sunday 08 December 2019
H1 SUS (SUS)
corey.gray@LIGO.ORG - posted 08:10, Sunday 08 December 2019 - last comment - 13:31, Tuesday 10 December 2019(53743)
ETMy MODE 18 (1000.30Hz) Rung Up

Around 14:55 notice H1 range took a step down at 13:37. 

Only obvious change was increase in 500-2000Hz bands via the BLRMS of DARM.  This lead me to look at violin modes and sure enough we had a big line on DARM spectra around 1kHz.  Looking at the Violin Mode medm Screen & DTT, it pointed toward: 

ETMy's MODE 18 (as well as a rung up MODE 20).

Unfortunately, I could not find newer instructions for damping violin modes (I could have sworn Rahul had something new because I remember Ed going through a procedure where he manipulated the VIOLIN_DAMPING guardian node.  The only Violin mode instructions I could find were the old ones Nutsinee wrote up.)  So after searching old alogs & through wikis for a few minutes, I then decided to take action:

Comments related to this report
rahul.kumar@LIGO.ORG - 13:31, Tuesday 10 December 2019 (53809)

Given below are the new links (effective from April 2019).

https://cdswiki.ligo-wa.caltech.edu/wiki/Violin_Mode_Table_v2/

and for the pdf file

https://cdswiki.ligo-wa.caltech.edu/wiki/Violin_Mode_Table_v2?action=AttachFile&do=get&target=Violin_damping_v1.pdf

Displaying report 1-1 of 1.