Lockloss with loss of light on the PSL

Near the end of my shift, H1 lost lock,  with a message about the PMC High Voltage.  I found the Diode Chiller was offit, and the NPRO power clearly shows that it's now off.

The only guardian error message was PMC High Voltage is OFF.

After talking to Jason, I went to the CER and looked at the PSL power supply(s).

Power supplies look OK, so it appears that the guardian error message may be a result of losing the chilller.

Attached are pictures of 3 the 3 PSL power supplies.