Displaying report 1-1 of 1.
Reports until 10:17, Wednesday 18 December 2019
H1 SQZ
sheila.dwyer@LIGO.ORG - posted 10:17, Wednesday 18 December 2019 - last comment - 13:23, Wednesday 18 December 2019(53965)
squeezer intervention this am

Corey, Sheila, Daniel, Keita

Summary: We are back to squeezing and in observing after having introduced some yaw offsets in the 42MHz WFS, for now this has addressed the problem that Jim describes in 53956.  It seems that the original problem is that the nonlinear gain has slowly degraded since the crystal move yesterday.  This issue cuased us to be out of observing for about 4 hours this morning, and in preventative maintence for a little while. 

  

Images attached to this report
Comments related to this report
corey.gray@LIGO.ORG - 10:31, Wednesday 18 December 2019 (53968)FRS

FRS #13979 started.

daniel.sigg@LIGO.ORG - 13:18, Wednesday 18 December 2019 (53971)

New crystal temp to re-optimize the non-linear gain: T = 33.256°C.

sheila.dwyer@LIGO.ORG - 13:23, Wednesday 18 December 2019 (53972)

Daniel, Sheila

While Jeff was calibrating, we closed the beam diverter and adjusted the crystal temperature while scanning the seed phase.  We got back to a nonlinear gain of 2.66, which should be fine.  

After re-injecting the squeezing, we have -28.6 dBm of 3MHz on the OMC DCPDs.  We tried turning off the yaw offsets in AS42 YAW, but saw that these offsets are still increasing OMC 3MHz, so we are leaving them on. 