Displaying report 1-1 of 1.
Reports until 13:37, Wednesday 18 December 2019
H1 SEI (OpsInfo)
jenne.driggers@LIGO.ORG - posted 13:37, Wednesday 18 December 2019 (53973)
SEI_CONF back to WINDY, CPS DIFF still off

At JeffK's suggestion, since the microseism has been coming down, we've transitioned back to our nominal WINDY seismic configuration.  However, the CPS DIFF is still off, since the microseism BLRMS is still above ~0.04 um/sec.  That seems to be about the level at which we started seeing glitches in Omicron.

So, if the microseism BLRMS is above 0.04 um/s (the units of the channels when viewed in ndscope is nm/s, so the value will be 400 nm/sec in ndscope for channels such as H1:ISI-GND_STS_ITMY_Z_BLRMS_100M_300M), let's keep CPS DIFF off.  If we go below that level, we can turn back on the CPS DIFF by setting

H1:ISI-DIFF_CONTROL_BIT to 1, or by opening the SEI DIFF controls screen and clicking ON in the lower righthand corner.  To get to that screen:

Displaying report 1-1 of 1.