Displaying report 1-1 of 1.
Reports until 08:10, Saturday 21 December 2019
H1 General
cheryl.vorvick@LIGO.ORG - posted 08:10, Saturday 21 December 2019 - last comment - 08:49, Saturday 21 December 2019(54026)
OPS Owl Summary

TITLE: 12/21 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
INCOMING OPERATOR: Camilla
SHIFT SUMMARY: locked in Observe

LOG:

Attachments:

  1. left:ETMY mode 6 damping filter bode plot, right: ETMX mode 6 damping filter bode plot, black = previous filter, red = new filter
  2. power spectra, showing ETMY modes 1 and 6
  3. power spectra, showing ETMX modes 1 and 6
Images attached to this report
Comments related to this report
cheryl.vorvick@LIGO.ORG - 08:49, Saturday 21 December 2019 (54029)

Violins - monitor filter updates:

  • I've updated the ITMX modes 7 and 8 Monitor Filters
  • these are ready to be loaded at next lockloss, or exit from Observe
  • these filter changes, and the ETMX damping filter change are showing up on the CDS overview as orange lights on H1SUSPROC and HISUSETMX
  • Camilla checked the times of these changes, and those times match my changes
Displaying report 1-1 of 1.