Mid-Shift Report: H1 Down 11:57UTC

All time in UTC:

There seems to have been a corner station system wide crash. H1 had been locked for 34:08

More news as it happens.....

Images attached to this report
Comments related to this report
edmond.merilh@LIGO.ORG - 08:02, Tuesday 31 December 2019 (54189)

12:28 Dave is beginning his remote magic

13:06 All WDs reset

13:07 Rotation stage seemed to be stuck at 47.8 W

  • Re-Initialized LASER_PWR Guardian node at 2W - successful

13:08 re-locking mode cleaner

  • IMC won't lock
  • following steps in WIKI
    • Called Cheryl for assistance