Reports until 19:11, Tuesday 31 December 2019
H1 SEI (SEI)
corey.gray@LIGO.ORG - posted 19:11, Tuesday 31 December 2019 - last comment - 10:09, Friday 03 January 2020(54203)
SEI_CONF to WINDY, but has FALSE Nominal Box

Decided to take SEI_CONF to the nominal WINDY state, but while there, notice that it has a FALSE state (i.e. orange box) for the NOMINAL box.   See attached screenshot with all suspects involved.

My guess would be that maybe it would be related to the BRSy Status being in the DAMPING state (N=30).  I trended this channel (H1:GRD-BRSY_STAT_STATE_N), and it's been in this state since 10:37am earlier today.  Maybe we need the winds to die down some more for it to get back to the READY (N = 40) state?  2nd Attachment is the last 12-14hrs showing BRSy switching to Damping for the last ~9hrs.

Texted Jim about this and he said we look normal, so will continue on and keep an eye on this.

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 10:09, Friday 03 January 2020 (54258)GRD, OpsInfo

The reason that SEI_CONF was FALSE was because someone had set themselves as the manager for ISI_ETMY_ST1_SC. If you look at the user message for SEI_CONF in the screenshot, it says "ISI_ETMY_ST1_SC: STOLEN (by:USER)".

As a reminder: Clicking the "MANAGE" button will make you the manager of the node, it will not give mangement back to the orginal manger.