Reports until 17:52, Thursday 07 February 2013
H1 DAQ
david.barker@LIGO.ORG - posted 17:52, Thursday 07 February 2013 (5423)
h1fw0 down this afternoon

Dan from LDAS worked on the h1ldasgw0 system to investigate why h1fw0 has become unstable since last Wednesday 30 Jan with apparent disk write slow downs. He upgraded the firmware, we then restarted the h1fw0 writer. Jim has made h1nds1 the default nds because of this problem so the shutdown had minimal impact.

After h1fw0 was restarted we restarted the DAQ due to an 0x2000 status on h1hpiham1. It appears that the model change earlier made channel number changes and a change in DQ channels (perhaps a common model was changed recently).