betsy.weaver@LIGO.ORG - posted 11:05, Thursday 10 February 2011 - last comment - 14:32, Thursday 10 February 2011(542)
FM1 testing
On Tuesday, Mark found that he could not actuate on the BS so after some verification that the coils looked good at the pseudo vacuum feed through on the mechanical stand, we called in the big guns.
Yesterday, Richard and Filiberto powered off bscteststand computer, blue IO chassis, powered on, started some code, rebooted, started the proper code code.  Stuff works now.  We're not entirely sure what fixed it, but putting an offset in the Test filter modules clearly pegs the coil dials now.
Comments related to this report
mark.barton@LIGO.ORG - 14:32, Thursday 10 February 2011 (543)
Comparing autoburt files before and after the reboot, Jeff and I deduced that the problem was that the On/Off switch associated with the watchdog had gotten turned off. (There's usually no need to touch it - it doesn't affect the operation of the watchdog and is just a simple enable/disable in series with it.)