Reports until 14:11, Tuesday 07 January 2020
H1 CDS
david.barker@LIGO.ORG - posted 14:11, Tuesday 07 January 2020 - last comment - 16:19, Tuesday 07 January 2020(54348)
SUS Damp Mode Gains now available as EPICS channels

WP8507

Camilla, TJ, Dave:

The L2 Damp Mode Gains values are now available as EPICS channels. Previously they were listed in the lscparams.py file.

This was a two part install:

 1. I created a new EPICS IOC to host the new channels. It is running on h1fescript0 and its details are available in this wiki page

 2. TJ made a modification to VIOLIN_DAMPING.py to write the gains to the new channels.

Now H1 has locked, the gain values have been updated to the EPICS PVs. I created an MEDM to show the 80 values (20 per test mass).

MEDM is /opt/rtcds/userapps/trunk/cds/h1/medm/SUS_VIOLIN_MODE_GAINS.adl

Images attached to this report
Comments related to this report
thomas.shaffer@LIGO.ORG - 14:31, Tuesday 07 January 2020 (54350)SUS

Populating these channels is done from the VIOLIN_DAMPING Guardian node in the DAMPING_SETTINGS state. It reads the lascparams.py file to get the gain settings, and then puts them into these channels. This way they are updated every lock. The relavant code:

    #set the settings for the modes that are damped on this test mass
    for mode, setting in modes.items(): # iterates through modes in lscparams

        # Add the lscparams gain values to the NORMALGAIN chan
            ezca['SUS-{}_L2_DAMP_MODE{}_NORMALGAIN'.format(sus, mode)] = setting['gain']

 

thomas.shaffer@LIGO.ORG - 16:19, Tuesday 07 January 2020 (54356)

I didn't give credit where credit is due, the above code is from Camilla. I loaded it in and watched it work.