Displaying report 1-1 of 1.
Reports until 04:13, Thursday 09 January 2020
H1 SUS
cheryl.vorvick@LIGO.ORG - posted 04:13, Thursday 09 January 2020 (54382)
ITMX damping filters/filter modiles adjusted for IX modes 2 and 3

after about 2 hours of trying to damp mode 3 with the filters that H1 has been using, with little to no effect, I talked to Jeff about changing the filters, since mode3 damping had always been mariginal. 

Changes to IX mode3:

Attachment 1: IX mode3 from abandoning the old filters to damping at relocking H1

Changes to IX mode2:

Attachment 2: IX mode 2 from unsuccessful redamping to (mostly) successful damping at relock

Other modes, other optics, damped by Jim:

Attachment 3:  IY mode 15

Attachment 4:  IY modes 1 and 6

- Jeff, Cheryl, Jim

Images attached to this report