Reports until 13:14, Thursday 09 January 2020
H1 CDS (SUS)
david.barker@LIGO.ORG - posted 13:14, Thursday 09 January 2020 (54391)
SUS violin mode gains detailed MEDM

Camilla, TJ, Dave:

The violin mode EPICS IOC was updated to also serve the MAXGAIN values (and VIOLIN_DAMPER.py was modified accordingly to write the max_gains).

The details of the gains are displayed in a new MEDM window H1SUS_VOILIN_MODE_GAINS.adl. This can be opened from the VIOLIN_ALL_MONITORS window via a 'Gains' related display button in the lower right.

The detailed gain window highlights those modes whose gains fall outside of the range defined by NOMINAL and MAX. In this case, a MAX=0 is assumed to have not been set and is ignored.

Images attached to this report