new and improved switch-front-end-sdf script

The old bash scripts switch_fec_sdf_to_safe and switch_fec_sdf_to_observe have now been replaced with a python program called switch_fec_sdf

usage: switch_fec_sdf [-h] subsys reference

Like its precedessors, for each model name which matches the subsys string, it switches the model's SDF reference to use its safe.snap or OBSERVE.snap file.

The code requires a confirmation, and lists the models which are to be switched.

# switch_fec_sdf h1ioppem observe
Please confirm the switching of the following models to OBSERVE
    h1ioppemmx
    h1ioppemmy
[y/N]:

The old switch_fec_sdf_to_safe and switch_fec_sdf_to_observe scripts are now wrappers to the new program.

Please email me if you have any problems with the new program.