Displaying report 1-1 of 1.
Reports until 16:12, Friday 10 January 2020
H1 PSL
yannick.lecoeuche@LIGO.ORG - posted 16:12, Friday 10 January 2020 (54417)
Issues with FSS during locking

[Jason, Niko, TJ, Jenne]

After a lockloss from RESONANCE that tripped the ISI-BS_STAGE_2 watchdog, FSS was having problems autolocking. Jason and TJ managed to get it re-locked, but later in locking POPAIR_B_RF18 would drop at CARM_TO_ANALOG and we would lose lock shortly afterward. Jenne noticed that the FSS common gain had been changed, and since this value is not hardcoded in GUARDIAN (because it gets changed whenever the FSS is adjusted by the PSL crew), it remained at the wrong value after we would lose lock. We're not sure how/why it got changed, perhaps if the FSS GUARDIAN reset partway through its common gain scan...(to be continued)

The FSS common gain was changed back to 20dB from -3dB, and we have reached NLN.

Displaying report 1-1 of 1.