edmond.merilh@LIGO.ORG - posted 12:21, Sunday 12 January 2020 - last comment - 12:28, Sunday 12 January 2020(54449)
Lockloss 19:39UTC
The range had been trending downward over the last hour. The wind speeds have been waxing and waning but not as treacherously high as they had been. (just had a 45mph gust as I was typing -_-). uSeism has leveled off just at the 90%ile mark.
winds are now sustained above 40mph at CS and some at MY
IMC/FSS became unlocked
a few quickish tugs on the FSS Autolocker seems to have done the
20:21 Failing at PRMI/ Intervening/ details in Lock Acquisition spreadsheet
Comments related to this report
edmond.merilh@LIGO.ORG - 12:28, Sunday 12 January 2020 (54450)
I suppose this will serve as my mid-shift summary:
PRMI had caught a lock twice but it was weak and couldn't withstand environmental conditions
environmental conditions are now such that winds are well above 40mph and I have switched SEI_CONF to USEISM_WINDY
My intervention with PRMI did NOT include CHECK_MICH_FRINGES. Rather I paused at PRMI_LOCKED and hand-aligned the BS to a better PRMI power and then passed it to the ASC loops and the rest of the "show"