Reports until 03:51, Monday 13 January 2020
H1 PSL (PSL)
corey.gray@LIGO.ORG - posted 03:51, Monday 13 January 2020 (54463)
PSL Status Report (FAMIS #11047)

    Laser Status:
    Front End Power is 32.32W (should be around 30 W)
    70W Output Power is 70.37W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 11 days, 16 hr 57 minutes (should be days/weeks)
    Reflected power = 11.51Watts
    Transmitted power = 52.38Watts
    PowerSum = 63.89Watts.

    FSS:
    It has been locked for 0 days 15 hr and 15 min (should be days/weeks)
    TPD[V] = 5.252V (min 0.9V)

    ISS:
    The diffracted power is around 2.5%
    Last saturation event was 0 days 15 hours and 15 minutes ago (should be days/weeks)