Reports until 12:23, Monday 20 January 2020
H1 General (PSL)
Link
camilla.compton@LIGO.ORG -
posted 12:23, Monday 20 January 2020
(54597)
H1 Lockloss 16:06 UTC
16:06
Lockloss
16:12 SEI_CONF to WINDY
17:09 SEI_CONF back to USEISM as lots of locklosses
17:10 Cleared OM1 and OM2 LOCK FILTERS histories as these were suspensions were saturating.
17:43 After 3 locklosses in CARM reduction states,
ran initial alignment
(as operator intervention thresholds suggests)
17:59 FFS unlocked during INITIAL ALIGNMENT in state PRC_ALIGNING (toggled auto-locker on 00 mode)
This happened during inital alignment in the same PRC_ALIGNING state yesterday
(
alog 54583
20:31 UTC)!
tagging PSL
18:43 SEI_CONF to WINDY
18:45 FFS wouldn't lock (toggled auto-locker on 00 mode)
19:21 NLN
CALCS rounding errors SDF diffs accepted
Same ETMX_M0_TEST_P/Y_OFFSET SDF diffs as yesterday reverted -
see attached
(something to do with initial alignment not reverting them maybe?!)
19:24
Observing.
Images attached to this report