SHIFT SUMMARY:
Xarm Access (tyler): All clear, but only single lane from MX to EX. (although we did have some 40mph winds after tumbleweed clearing!) :-/
Fairly light Maintenance Day with H1 relocking fairly easily. Ended shift with Commissioning time by Sheila/Camilla.
LN2 delivery at MX (CP6) is due
LOG:
- Before 16:00:
- H1 Locked (not Observing) and Cheryl completing Weekly PEM Injection.
- Tumbleweed clearing at the very end of EX (tyler.scott)
- 16:00 SEI_CONF to SC_OFF_NOBRSXY
- H1 lockloss within seconds after.
16:04 Cleaning EY (karen)----This was canceled.
- 16:08 Cleaning LVEA (Vanessa)
- 16:10-16:32 Photos of IO Calcite wedge by aligning PRM, also turning ON illuminator (Cheryl)
- 16:15-17:39 HEPI/Dust Maintennance (Jeff B)
- 16:24-17:20 ISCT6 PD install / Laser Curtains UP! (Shiela, Camilla)
- 19:08 Installed dump in front of this new PD (Sheila)
- 16:49-17:39 Network Switch affecting cameras (fil, carlos)
- 16:47 - 18:18 EY End Station Calibration (niko, ethan)
- 16:56 - 18:40 LN2 delivery at LVEA CP1 (#75)
- 16:56 -19:40 Plugging in all electric vehicles for charge in LVEA (Chris)
- 17:11 Ace toilets
- 17:15 SEI HAM transport tooling (hugh.scott)
- 17:31 Looking for tools at EX (Gerardo)
- 17:36 - 18:34 ITMy Noisemon testing (Sheila)
- 17:49 ISC RF cable relabling (Fil)
- 18:14 X-arm drive (Christina)
- 18:29 -19:50 EY Mechanical Room trip (Kyle)
- 18:39 Updating DMT (greg. madeline)
- 19:13 SEI_CONF to WINDY
- 19:15 Began locking
- PRM was left in ALIGNED (this made it hard to FIND_IR)
- Couldn't lock green arms with SEI_CONF in SENCOR_OFF_NOBRSXY
-
- ~20:00-21:00 Network switch work from earlier didn't take, so Carlos & Fil reinstalling the original Network switch
- 21:00 LVEA Swept (Corey)
- 21:28 OBSERVING
- 21:33 out of Observing to reboot a camera server (Carlos)
- 21:36 OBSERVING
- 22:10 Separate trips to MY (Scott, Kyle back at 23:24)
- 23:07 Commissioning Time for ISCT6's new PD. (Sheila, Camilla)
- NOTE: AS Beam Diverter was Opened by Sheila and H1 did not drop out of OBSERVING.
- 23:54 Quick trip to MX (Gerardo).