Displaying report 1-1 of 1.
Reports until 12:27, Tuesday 21 January 2020
H1 CDS
david.barker@LIGO.ORG - posted 12:27, Tuesday 21 January 2020 - last comment - 13:59, Tuesday 21 January 2020(54622)
Script to clear all open testpoints

I have written a python script to clear all open testpoints. To run it from the command line:

clear_all_testpoints

It can also be ran from the CDS Overview MEDM screen by pressing the 'ClearTestPoints' button in the lower right corner of the screen.

In both cases, if there are testpoints to be cleared a confirmation message is displayed (see attachment). If confirmed, then the open testpoints are cleared.

Note that the h1calinj model is exempted from this due to hardware injection testpoints.

Images attached to this report
Comments related to this report
david.barker@LIGO.ORG - 13:59, Tuesday 21 January 2020 (54628)

As an added bonus, I've added the corner station weather channels to the top banner on the cds overview MEDM.

Images attached to this comment
Displaying report 1-1 of 1.