TITLE: 01/23 Day Shift: 16:00-00:00 UTC (08:00-16:00 PST), all times posted in UTC
STATE of H1: Observing at 118Mpc
INCOMING OPERATOR: Ed
SHIFT SUMMARY:
There was COMMISSIONING time (1hr51min) today.
SEI_DIFF has been in the CORNER_DIFF_CPS state, but Jim noted that since microseism signals are below the 90th percentile, we could switch SEI_DIFF to FULL_DIFF_CPS...with low microseism, this would mainly help us ride through and acquire better with higher winds.
LOG:
- 16:05 Clearing tumbleweeds for Anemometer move at EX (Scott, Chris)
- 16:51, 19:42 MX trip (Vanessa)
- 18:00-18:47 MY cleaning (Karen
- Noticed on DIAG MAIN: BRS_CHECK: BRS X C code has stopped
- 18:10 - 21:05 Anemometer move (Scott, Hugh)
- 19:08:31 (gps 1263841729) Time when Wind Sensor #5 (direction sensor) plugged in by Hugh.
- 19:31:39 (gps 1263843117) Time when 2nd Sensor plugged in.
- 20:19:14 (gps 1263845972) Time when 3rd sensor plugged in.
- 21:32 EQ Alert (5.5 N. Argentina), will monitor.
- 21:34 - 23:25 COMMISSIONING time begins; also coordinated with LLO.
- 21:34 DRMI Guardian reloaded (Camilla, Jenne)
- 21:36 SEI_DIFF transitioned to FULL_DIFF_CPS since we have low microseism & this can help us with winds.
- 21:37 - 23:25 Out on floor for SQZ Mode matching/alignment (Sheila, Camilla)
- 21:58 - 22:35 Forklifting items from LSB Receiving to Fire Water Tank Sea-Container. (Tyler, Scott)
- 22:45 -22:47 Benton Sheriff vehicle (SUV w/ lights flashing) sped into site & turned around at LSB Parking lot. No contact made.
- 22:57 - 22:59 Hanford Patrol also entered (both vehicles hung a right toward SR 240).