Camilla, Jason, Sheila, Jenne
Looking at two short time periods where we've had lots of unknown lock losses, I have found that there seems to be a correlation with the time of the lockloss being within milliseconds of the PSL Ref Cav Transmitted photodiode and PSL PZT oscillating (Yellow and green channels in
attachment and
zoomed version). I haven't fully investigated, but this seems to
not happen when we know the reason of our lockloss, see
EQ attachment for example when we lost lock from EQ and there is no FFS oscillation.
Times I have found: 2020-01-21 13:37:29 UTC, 2020-01-21 04:12:13 UTC, 2020-01-20 04:08:49 UTC, 2019-01-12 19:38:13 UTC, 2019-01-12 15:30:36 UTC, 2019-01-12 10:07:31 UTC, 2019-01-11 07:17:56 UTC,