LSC: no diffs that are monitored. Also checking not monitored channels since we're restarting the model today, and I agree that all of them will be set by guardian before we need them, so no changes there need attention.
SUSPROC: 3 diffs for ETMY mode 7. Accepting, since these are the same as Cheryl recently put in a few days ago (alog 54667) to have monitor filters.
ALSEY: Accepting lower thresholds for autocentering (last changed ~2 weeks ago).
Only other SDF diffs are the usual ISI BS with 23 differences.
Thanks Jenne.
I added two test points in the LSC model, H1:LSC-POPAIR_B_RF18_I_ERR_16k and H1:LSC-POPAIR_B_RF90_I_ERR_16k and added them to the DQ list. I did the make and the make install. This is for getting the lockloss timing better, motivated by Camilla and Jason finding some very fast locklosses where there seems to be a large transient in the FSS almost at the time of the lockloss. We'd like to get a better resolution on the timing of the lockloss, to compare to the 16kHz timing of the PSL channels.
The ECR for this is E2000067. This is really a test for LHO only for now, we'll see if this is helpful.