Following on from 21:57 UTC Lockloss, as in Jim's alog 54795. We currently have microseism up at 0.80 μm/s which probably helped make this acquisition 6 hours long!
During states LOW_NOISE_COIL_DRIVERS and TRANSITION_FROM_ETMX we had DIAG MAIN give this messages that AS and REFL beam diverters aren't closed. Sheila assured me that this is due to a guardian re-shuffle and isn't a problem, but maybe we could remove these warnings.