Displaying report 1-1 of 1.
Reports until 15:00, Tuesday 12 February 2013
H1 SUS
mark.barton@LIGO.ORG - posted 15:00, Tuesday 12 February 2013 - last comment - 09:49, Friday 15 February 2013(5473)
PR3 TFs
Deepak and Bubba report they're done for the day, so commencing Matlab TFs on PR3.
Comments related to this report
mark.barton@LIGO.ORG - 07:14, Wednesday 13 February 2013 (5481)
Data taken, apparently successfully, plots pending.

Undamped: ^/trunk/HLTS/H1/PR3/SAGM1/Data/2013-02-12-1044746361_H1SUSPR3_M1_0p01to50Hz_tf.mat

Damped: ^/trunk/HLTS/H1/PR3/SAGM1/Data/2013-02-12-1044766428_H1SUSPR3_M1_0p01to50Hz_tf.mat
mark.barton@LIGO.ORG - 09:49, Friday 15 February 2013 (5509)
Plots finally - all good. This is a pass for Phase 2b TFs. Phase 2b spectra were waiting on some adjustments to the M3 OSEMs per alog 5499 (since fixed) and will be taken soon.
Non-image files attached to this comment
Displaying report 1-1 of 1.