Relocked from 10:46 (02:46) lock loss at 11:53 (03:53). Auto relocking went reasonably well.
(1). Had to toggle the FSS AUTOLOCKER three times to get it to lock on the correct mode. Thanks for directions in aLOG #54445
(2). Lost lock twice at LOCKING_ALS - Possibly due to an Earthquake from Mexico rolling through.
Had DIFF Beat Note Low message before the LOCKING_ALS lock loss
(3). Took two ACQUIRE_DRMI_1F and one ACQUIRE_PRMI pass to get DRMI to lock
(4). The lock went the rest of the way to NLN with out difficulties. There were no SDF DIFFs.
We are now back up and running with a 117.8Mpc range. The wind has dropped down from the 20mph with 30 mph plus gusts, to below 10 mph. All looking good for second half of the shift.