Reports until 10:16, Friday 07 February 2020
H1 PSL
yannick.lecoeuche@LIGO.ORG - posted 10:16, Friday 07 February 2020 (54968)
PSL Status Report-Weekly

 Laser Status:
    Front End Power is 32.4W (should be around 30 W)
    70W Output Power is 70W
    Front End Watch is GREEN
    70W Watch is GREEN

    PMC:
    It has been locked 9 days, 22 hr 37 minutes (should be days/weeks)
    Reflected power = 11.7Watts
    Transmitted power = 51.9Watts
    PowerSum = 63.6Watts.

    FSS:
    It has been locked for 0 days 16 hr and 3 min (should be days/weeks)
    TPD[V] = 5.367V (min 0.9V)

    ISS:
    The diffracted power is around 2.5%
    Last saturation event was 0 days 16 hours and 2 minutes ago (should be days/weeks)

    Possible Issues: