Displaying report 1-1 of 1.
Reports until 08:09, Tuesday 11 February 2020
LHO General
patrick.thomas@LIGO.ORG - posted 08:09, Tuesday 11 February 2020 (55027)
Ops Owl Shift Summary
TITLE: 02/11 Owl Shift: 08:00-16:00 UTC (00:00-08:00 PST), all times posted in UTC
STATE of H1: Preventive Maintenance
INCOMING OPERATOR: Ed
SHIFT SUMMARY: One lock loss from Observing. Not able to relock until ~9 min before start of maintenance. PEM injections not run.
LOG:

~08:33 UTC Restarted NCAL EX PLC and EPICS IOC. EDCU is now green.

12:32 UTC Lock loss.
PSL_FSS: PZT MON is high, may be oscillating
12:38 - 12:41 UTC Toggled the FSS autolocker
12:41 UTC FSS relocked
INCREASE_FLASHES took about 10 min
13:07 UTC Lock loss from ACQUIRE_DRMI_1F
13:17 UTC Lock loss from OFFLOAD_DRMI_ASC
13:20 UTC Lock loss from FIND_IR
13:23 UTC Restarted Unifi WAP IOC on opslogin
13:23 UTC Lock loss from FIND_IR
Pausing at CHECK_IR. Adjusted COMM_OFFSET.
13:31 UTC Done pausing at CHECK_IR
13:33 UTC Lock loss from ACQUIRE_DRMI_1F
13:56 UTC Lock loss from MOVE_SPOTS
14:05 UTC Lock loss from OFFLOAD_DRMI_ASC
Starting initial alignment
14:27 UTC Initial alignment complete
14:49 UTC Lock loss from MOVE_SPOTS
14:55 UTC Lock loss from CHECK_IR
15:15 UTC Lock loss from MOVE_SPOTS
15:22 UTC Driving forklift from LSB to carpenter's shop
15:27 UTC Jeff B. to end stations for HEPI and dust monitor checks
15:34 UTC Pausing at POWER_10W.
15:37 UTC Done pausing
15:40 UTC Tyler and Chris to end X to remove tumbleweeds from around LN2 dewer
15:51 UTC NLN
15:55 UTC Observing
16:01 UTC Out of observing for maintenance. Took SEI_CONF to SC_OFF_NOBRSXY.