Displaying report 1-1 of 1.
Reports until 21:33, Tuesday 11 February 2020
H1 CDS
david.barker@LIGO.ORG - posted 21:33, Tuesday 11 February 2020 (55058)
CDS Maintenance Summary: Tuesday 11th February 2020

SEIPROC add ramped mux matrix

Jim, Dave:

Jim installed a new h1seiproc, which removes the P5_FADER code section and adds four 2-element ramped mux matrix parts (one per test mass).

New guardian node IFO_NOTIFY

TJ, Dave:

The new guardian node creates a state which will permit the lock loss alerting system to notify that there are locking issues which need attention. I modified the lock-loss-alert code to service this request and the new code is being tested.

DAQ Restart:

For above changes. h1edc was restarted for the guardian node addition.

Slow Controls EX temporary photodiode removal, MEDM modified

Richard, Dave:

The EX slow controls system will run in a hardware error state for the next week. To 'UN_RED' the CDS overview screen, I have taken EX out of the condition to make the large red header block visible. The EX small red rectangle will remain RED. Image of the new nominal is attached.

Images attached to this report