As a follow up on 54969 we are out of observing for 40 minutes with the squeezer off. We spent the first 20 minutes (20:07:40-20:28:00 UTC Feb 13th) at a DARM offset of 4.8pm which gave us 4.9mA of DCPD current. We went to a DARM offset of 13.9pm which gives us a current of 40.9 mA at 20:29:56 UTC and we will stay here until 20:50 UTC.
In the mean time I also loaded the noise mon calibrations that Chris posted here. I turned these filters on so that the noisemons should now be calirbated into units of DAC counts. screenshot of SDF accepts for the end stations is attached, the same was done for the ITMs.