Reports until 00:07, Friday 14 February 2020
H1 General
cheryl.vorvick@LIGO.ORG - posted 00:07, Friday 14 February 2020 - last comment - 00:39, Friday 14 February 2020(55091)
OPS Eve Summary

TITLE: 02/14 Eve Shift: 00:00-08:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 119Mpc
INCOMING OPERATOR: Patrick
SHIFT SUMMARY: locked all shift
LOG:

Comments related to this report
cheryl.vorvick@LIGO.ORG - 00:39, Friday 14 February 2020 (55092)

Damped ETMY modes 12 and 20.  Attached plots show the past 8 hours and a zoom in on gains while damping modes 12 and 20.

  • Mode 11 was turned off by guardian, left off, tried damping with nominal gains, rung up mode 12
  • mode 12 damped with -60deg phase (matches mode 20), was able to increase mode 12 gain to 4 (mode 11 gain = 0)
    • ETMY mode 12 FM4, -60deg phase, unmonitored in SDF
  • mode 18 damped with less gain, 5 instead of 10
  • mode 20 damped with a gain of 1.7, but started at 0.1, then increased in steps of 0.1-0.3
  • modes 12, 18, and 20 damped with these settings at the same time (previously mode 18 damping had to be off to damp mode 20)
  • reduced gains on other modes that had low RMS
  • bonus, violin peaks at 1.5K reduced
  • all damping restored to nominal
Images attached to this comment