Displaying report 1-1 of 1.
Reports until 07:48, Friday 14 February 2020
H1 SEI
patrick.thomas@LIGO.ORG - posted 07:48, Friday 14 February 2020 - last comment - 10:39, Friday 14 February 2020(55097)
Did verbal miss an earthquake notification?
I think there may have been a 4.6 magnitude earthquake in Canada at 11:17:05 UTC that qualified for changing SEI_CONF to EARTH_QUAKE, but did not get announced by verbal.
Images attached to this report
Comments related to this report
jim.warner@LIGO.ORG - 09:58, Friday 14 February 2020 (55101)

Probably seismon got the report after the earthquake arrived, it was only around 1k km away. Probably would have to be almost twice that to actually get advanced warning. I don't remember all of the details but there is only a short window where there will be a verbal notification after seismon predicts the earthquake will arrive.

thomas.shaffer@LIGO.ORG - 10:39, Friday 14 February 2020 (55102)

Since this was a close earthquake, it looks like when Seismon updated, it had a negative time. Verbal will ignore negative times because it thinks the earthquake has passed.

EDIT: Jim Beat me to the answer.

Displaying report 1-1 of 1.