Reports until 15:41, Monday 24 February 2020
H1 AOS
philip.jones@LIGO.ORG - posted 15:41, Monday 24 February 2020 - last comment - 12:03, Tuesday 10 March 2020(55265)
ASC Sensing Matrix Measurement

Took ASC sensing matrix measurement with 'userapps/asc/h1/scripts/sensingMatrix/run_sensmat.py', using updated injection amplitudes. DHARD & CHARD yaw were too low to get a coherent measurement, I've left a note for next time.

ASC Sensing Matrix (Pitch), [W/rad]

dof: DHARD CHARD DSOFT CSOFT
AS_A_DC_PIT 7.4e+04 118 1.7e+02 -60 4.6e+02 66 3.6e+02 86
AS_A_RF36_I_PIT 1.1e+06 -16 2.3e+03 13 1.37e+05 163 2.1e+04 -170
AS_A_RF36_Q_PIT 1.3e+06 -80 9.2e+03 157 2.17e+05 156 2.4e+04 -125
AS_A_RF45_I_PIT 3.0e+05 18 3.98e+03 -130 8.57e+03 170 9.39e+03 11
AS_A_RF45_Q_PIT 8.54e+05 -24 1.53e+04 -171 1.43e+04 -119 2.09e+04 -8
AS_B_DC_PIT 2.7e+04 -83 3.3e+02 -49 6.0e+02 161 8.8e+02 -135
AS_B_RF36_I_PIT 2.9e+06 37 1.7e+04 -57 2.52e+05 -19 1.1e+05 168
AS_B_RF36_Q_PIT 3.5e+06 -162 1.3e+04 148 2.24e+05 -24 5.4e+04 -24
AS_B_RF45_I_PIT 1.2e+05 -29 3.22e+03 176 7.94e+03 -162 5.5e+03 100
AS_B_RF45_Q_PIT 7.70e+05 157 8.82e+03 39 1.01e+04 29 1.98e+04 154
AS_C_PIT 1.6e-02 58 5.49e-04 -69 1.55e-03 -119 1.0e-03 109
REFL_A_DC_PIT 4.1e+04 150 3.6e+02 -103 1.7e+03 -87 3.1e+03 155
REFL_A_RF9_I_PIT 7.1e+06 137 2.42e+05 168 1.9e+05 -117 4.7e+05 135
REFL_A_RF9_Q_PIT 7.4e+06 -7 9.76e+04 -12 6.0e+04 24 2.3e+05 -38
REFL_A_RF45_I_PIT 6.3e+06 107 3.42e+05 172.9 1.9e+05 -88 2.2e+05 147
REFL_A_RF45_Q_PIT 3.1e+06 52 1.01e+05 171 3.1e+04 88 1.3e+05 -17
REFL_B_DC_PIT 1.6e+04 48 5.4e+02 173 7.7e+02 -66 3.4e+03 137
REFL_B_RF9_I_PIT 4.5e+06 130 1.71e+05 162 6.8e+04 -120 1.5e+05 147
REFL_B_RF9_Q_PIT 1.4e+06 -3 4.80e+04 -15 2.3e+04 -69 3.0e+04 -10
REFL_B_RF45_I_PIT 3.0e+07 143 3.26e+05 161 3.6e+05 -105 3.0e+05 110
REFL_B_RF45_Q_PIT 9.6e+06 146 1.03e+05 160 1.1e+05 -110 6.7e+04 88
POP_X_RF_I_PIT 2.7e+06 -3 1.62e+05 -16 9.3e+04 158 2.2e+05 -37
POP_X_RF_Q_PIT 3.3e+06 -97 2.3e+04 172 2.5e+04 -3 4.2e+04 164
POP_A_PIT 3.8e+03 -119 7.81e+01 -28 2.2e+01 92 9.0e+01 -55
POP_B_PIT 3.1e+02 148 1.34e+01 143 1.2e+01 72 7.2e+00 -152
X_TR_A_PIT 2.5e+03 -179 4.31e+03 157 1.01e+02 -3 1.8e+02 -32
X_TR_B_PIT 3.5e+03 -166 5.29e+03 157 2.89e+02 159 3.46e+02 164
Y_TR_A_PIT 6.2e+03 -20 5.37e+03 159 3.78e+02 163 3.3e+02 -6
Y_TR_B_PIT 4.0e+03 -80 1.53e+03 156 7.75e+02 -22 7.37e+02 167

ASC Sensing Matrix (Yaw), [W/rad]

dof: DHARD CHARD DSOFT CSOFT
AS_A_DC_YAW 8.1e+04 40 7.6e+03 157 5.1e+02 -169 4.0e+02 -2
AS_A_RF36_I_YAW 3.8e+06 -129 9.0e+04 52 1.12e+05 -12 6.37e+04 167
AS_A_RF36_Q_YAW 4.7e+06 -154 1.2e+05 -75 2.05e+05 -19 2.4e+04 -22
AS_A_RF45_I_YAW 3.3e+05 0 1.1e+04 87 1.02e+04 20 3.1e+03 -22
AS_A_RF45_Q_YAW 9.0e+05 -5 1.7e+04 127 1.12e+04 57 4.8e+03 40
AS_B_DC_YAW 6.6e+04 -84 2.5e+03 128 6.6e+02 49 3.1e+02 -17
AS_B_RF36_I_YAW 3.8e+06 -118 1.7e+05 -60 2.11e+05 167 1.2e+05 145
AS_B_RF36_Q_YAW 4.2e+06 154 3.9e+05 117 2.26e+05 156 9.3e+04 -49
AS_B_RF45_I_YAW 1.8e+05 -23 1.7e+04 -130 6.14e+03 -19 2.1e+03 69
AS_B_RF45_Q_YAW 8.7e+05 -173 2.4e+04 -26 1.21e+04 -78 8.2e+03 172
AS_C_YAW 1.4e-01 -175 4.2e-03 -4 1.44e-03 143 6.2e-04 -147
REFL_A_DC_YAW 2.8e+05 -75 1.7e+04 -137 2.3e+03 52 3.2e+03 97
REFL_A_RF9_I_YAW 4.5e+07 -69 2.1e+06 -116 1.3e+05 171 3.0e+05 108
REFL_A_RF9_Q_YAW 7.2e+06 -116 3.1e+05 -17 5.6e+04 -136 2.5e+04 144
REFL_A_RF45_I_YAW 1.2e+08 -82 7.1e+06 -96 5.2e+05 -175 8.1e+05 133
REFL_A_RF45_Q_YAW 2.8e+07 -88 2.0e+06 -91 1.6e+05 -177 1.7e+05 152
REFL_B_DC_YAW 5.6e+04 -166 1.3e+04 -86 6.3e+02 -23 1.3e+03 141
REFL_B_RF9_I_YAW 9.9e+06 96 6.3e+05 165 4.7e+04 28 1.25e+05 -13
REFL_B_RF9_Q_YAW 1.6e+06 137 3.5e+05 11 1.5e+04 163 6.6e+04 170
REFL_B_RF45_I_YAW 5.8e+07 102 2.4e+06 108 3.0e+05 158 2.1e+05 -6
REFL_B_RF45_Q_YAW 1.9e+07 111 8.1e+05 76 8.2e+04 -169 5.0e+04 -34
POP_X_RF_I_YAW 8.1e+06 175 1.1e+06 7 8.6e+04 -145 1.4e+05 175
POP_X_RF_Q_YAW 4.6e+06 87 2.3e+05 -50 7.1e+04 -24 4.8e+04 -36
POP_A_YAW 7.2e+03 7 6.8e+02 -164 1.6e+02 -45 9.8e+01 -59
POP_B_YAW 2.3e+03 11 7.7e+01 84 3.9e+01 -38 9.4e+00 46
X_TR_A_YAW 5.2e+03 -76 4.39e+03 161 1.2e+02 -168 1.8e+02 129
X_TR_B_YAW 6.6e+03 -93 3.22e+03 169 7.96e+02 -23 6.17e+02 -23
Y_TR_A_YAW 9.0e+03 177 5.50e+03 -24 2.7e+02 147 2.8e+02 -14
Y_TR_B_YAW 1.2e+04 165 2.72e+03 -22 6.74e+02 -31 6.24e+02 166
Comments related to this report
philip.jones@LIGO.ORG - 14:26, Wednesday 26 February 2020 (55318)

Updated yaw sensing matrix, with DHARD & CHARD inputs increased by a factor of 3:

ASC Sensing Matrix (YAW), [W/rad]

dof: DHARD CHARD DSOFT CSOFT
AS_A_DC_YAW 2.8e+04 -152 2.2e+03 -25 4.6e+02 -100 4.0e+02 108
AS_A_RF36_I_YAW 6.3e+05 -177 9.6e+04 -84 1.22e+05 -18 5.7e+04 130
AS_A_RF36_Q_YAW 1.6e+06 -28 5.4e+04 -49 1.98e+05 -15 1.9e+04 -39
AS_A_RF45_I_YAW 3.73e+05 -6 1.31e+04 164 1.11e+04 5 1.4e+03 16
AS_A_RF45_Q_YAW 9.41e+05 -22 2.9e+04 174 1.50e+04 47 3.5e+03 105
AS_B_DC_YAW 1.7e+04 37 1.7e+03 -96 3.8e+02 -43 4.9e+02 -50
AS_B_RF36_I_YAW 1.2e+06 -169 1.2e+05 -52 2.20e+05 162 7.1e+04 107
AS_B_RF36_Q_YAW 7.5e+05 -111 1.4e+05 171 1.96e+05 169 1.7e+04 -50
AS_B_RF45_I_YAW 8.6e+04 -47 7.8e+03 -163 6.00e+03 -12 4.9e+03 68
AS_B_RF45_Q_YAW 7.93e+05 161 2.96e+04 -4 1.10e+04 -91 4.5e+03 -105
AS_C_YAW 4.94e-02 -163 1.9e-03 -38 1.2e-03 129 7.9e-04 -126
REFL_A_DC_YAW 4.0e+04 -56 7.3e+02 -37 1.2e+03 109 7.2e+02 -7
REFL_A_RF9_I_YAW 1.9e+06 131 2.7e+05 82 2.1e+05 80 8.3e+04 63
REFL_A_RF9_Q_YAW 1.2e+06 -168 3.5e+05 18 4.0e+04 23 3.0e+04 68
REFL_A_RF45_I_YAW 8.0e+06 149 1.9e+06 36 7.2e+05 65 2.3e+05 49
REFL_A_RF45_Q_YAW 3.3e+06 133 6.9e+05 38 2.2e+05 56 7.8e+04 52
REFL_B_DC_YAW 1.6e+04 -94 3.1e+03 20 2.6e+02 106 7.8e+02 -36
REFL_B_RF9_I_YAW 1.4e+06 8 3.85e+05 154 4.4e+04 103 9.6e+04 -4
REFL_B_RF9_Q_YAW 5.3e+05 124 1.2e+05 -94 4.4e+04 -122 4.7e+04 -166
REFL_B_RF45_I_YAW 3.4e+06 43 1.3e+06 -169 2.6e+05 -127 1.2e+05 -167
REFL_B_RF45_Q_YAW 2.6e+05 -110 2.6e+05 -147 1.0e+05 -116 4.8e+04 -93
POP_X_RF_I_YAW 2.0e+06 -172 2.9e+05 -58 1.2e+05 -104 5.4e+04 179
POP_X_RF_Q_YAW 7.1e+05 161 9.7e+04 -169 3.7e+04 -75 7.3e+04 118
POP_A_YAW 1.1e+02 -48 7.16e+01 -21 6.4e+00 45 3.7e+00 -50
POP_B_YAW 6.0e+02 -50 5.84e+01 159 8.9e+00 -124 1.0e+01 148
X_TR_A_YAW 5.3e+03 165 3.53e+03 159 1.6e+02 -120 4.5e+01 -31
X_TR_B_YAW 3.6e+03 167 2.73e+03 160 7.08e+02 -26 6.96e+02 -32
Y_TR_A_YAW 7.1e+03 159 6.04e+03 -20 3.69e+02 156 2.8e+02 -10
Y_TR_B_YAW 4.3e+03 152 2.01e+03 -25 7.64e+02 -22 6.72e+02 151
philip.jones@LIGO.ORG - 12:03, Tuesday 10 March 2020 (55529)

The whitening / anti-whitening gains in runAnalysis_vII.py were outdated. Attached are the tables with corrected gains, and also in raw cts/rad.

Non-image files attached to this comment