Squeezer oscillations not solved by cycling guardian; green power lowered

[Sheila, Keita, TJ, Jenne]

As we were finishing relocking, the squeezer manager wasn't happy, because the SQZ_LO_LR guardian wasn't getting to its nominal state and returning True because the standard deviation of H1:SQZ-OMC_TRANS_RF3_DEMOD_RFMON was too high.  In the end, we've lowered the green power slightly, and the squeezer is back, and we're ready to go to Observing after the current calibration measurement is complete.  On the one hand, we apologize for the glitches that this will have caused in the calibration data (although hopefully they are short enough to not be troublesome), but on the other hand we were out of observing anyway, so we didn't actually lose observing time due to this squeezer issue.

Also, when relocking the OPO Sheila noted that it looks like OPO didn't lock at the top of the peak, so Sheila is going to look at how this compares to the last time we moved the crystal to determine if we should find a new spot on the crystal during the long Tuesday maintenance.  The second attached screenshot shows in the top left corner that the OPO Trans isn't at the peak after it is locked. 

Images attached to this report
Comments related to this report
jenne.driggers@LIGO.ORG - 17:38, Thursday 27 February 2020 (55340)OpsInfo

If the squeezer is not working sometime over night or over the weekend, and cycling the squeezer guardian doesn't fix the problem, you can try lowering the green power further so that we can get back to Observing with some squeezing, rather than having to Observe with no squeezing at all.  We hope that this will not be necessary.

  1. Sitemap -> SQZ_OVERVIEW screen. 
  2. Click the little blue AOM block just under the text "SHG Rejected", about 2/3 of the way down the squeezer overview screen near the left side (not to be confused with the 2 AOM blocks that are next to each other near the very bottom of the screen). 
  3. The slider that you will adjust is in the bottom left corner of that screen, and the channel is called H1:SQZ-OPO_ISS_SETPOINT. 
  4. Watch H1:SQZ-OPO_TRANS_DC_NORMALIZED.
    1. You can find this channel already on an ndscope from the SQZ Scopes button near the top right of the squeezer overview screen, locking signals, then it's in the top left panel. 
  5. Move the ISS Setpoint slider until the OPO_trans_DC_normalized is lowered and the oscillations have stopped.
  6. Alog the fact that this was neccessary, screenshot, accept, and post SDF diffs, and go back to Observing. 
    1. Commissioning team will take a look at next opportunity, and may adjust the temperature and squeezer angle.