Reports until 17:35, Sunday 01 March 2020
H1 SEI
camilla.compton@LIGO.ORG - posted 17:35, Sunday 01 March 2020 - last comment - 12:34, Monday 02 March 2020(55366)
Dropped out of Observing (for 30 seconds) at 00:49UTC

It seems like the node that casued us to drop out of observing was due to an automatic SEI_CONF change EQ>WINDY>EQ, maybe due to EQ being requested before we were fully transitioned to WINDY. Details follow:

2020-03-02_00:49:09.429949Z IFO [OBSERVE.run] USERMSG 0: waiting for node: DIAG_CRIT
2020-03-02_00:49:09.274144Z DIAG_CRIT [RUN_TESTS.run] USERMSG 0: SEI_CONFIG_ACTIVE: HPI_BS_SC not ACTIVE
Comments related to this report
jim.warner@LIGO.ORG - 11:38, Monday 02 March 2020 (55374)GRD

Looking at the logs, it looks like the HPI_BS_SC node may have stalled, which could be due to a known bug in the sensor correction parts of the simulink models. The ISIs have been restarted to address the bug, but the HEPIs may not have been. I need to get some help from Dave to determine if the HEPIs are running the most recent code or not, but it's possible we have a way to prevent this happening down the road.

thomas.shaffer@LIGO.ORG - 12:34, Monday 02 March 2020 (55375)GRD

This was actually a case where the worker for the Guardian node itself was terminated and then restarted. I don't why the worker timed out, but recovery was quick.

Images attached to this comment