J. Kissel Full suite of standard calibration measurements on the ETMX actuator and the sensing function, again hoping to reduce the uncertainty on the unknown systematic error, like last week (see LHO aLOG 55262 and latest estimate of uncertainty [which does not yet include the last two weeks of measurement,] LHO aLOG 55055). Detector in its nominal O3B configuration with 38 W input to the IMC (33.6 W in to PRM), a 50ct SRCL offset in order to "retune" the sensing function. (SQZ engaged, medium-to-low wind and medium mircoseism.) Raw DTT templates with the data has been committed and exported here: /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs 2020-03-02_H1_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml 2020-03-02_H1_PCALY2DARMTF_LF_SS_5t1100Hz_10min.xml 2020-03-02_H1_PCALY2DARMTF_BB_3min.xml << starts at 2020-03-02 19:00:32 UTC (for offline GDS processing.) /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOActuationTFs 2020-03-02_H1SUSETMX_L1_iEXC2DARM_8min.xml 2020-03-02_H1SUSETMX_L1_PCAL2DARM_5min.xml 2020-03-02_H1SUSETMX_L2_iEXC2DARM_12min.xml 2020-03-02_H1SUSETMX_L2_PCAL2DARM_6min.xml 2020-03-02_H1SUSETMX_L3_iEXC2DARM_12min.xml 2020-03-02_H1SUSETMX_L3_PCAL2DARM_6min.xml Will get to including these and other data sets in the uncertainty budget when I can.