Laser Status:
Front End Power is 32.08W (should be around 30 W)
70W Output Power is 69.49W
Front End Watch is GREEN
70W Watch is GREEN
PMC:
It has been locked 6 days, 20 hr 7 minutes (should be days/weeks)
Reflected power = 11.83Watts
Transmitted power = 51.9Watts
PowerSum = 63.73Watts.
FSS:
It has been locked for 3 days 16 hr and 54 min (should be days/weeks)
TPD[V] = 5.523V (min 0.9V)
ISS:
The diffracted power is around 2.5%
Last saturation event was 3 days 16 hours and 52 minutes ago (should be days/weeks)
Possible Issues: No apparent issues at this time.