FAMIS9532
2020-03-03 08:45:08.355362
There are 1 STS proof masses out of range ( > 2.0 [V] )!
STS B DOF X/U = -2.291 [V]
All other proof masses are within range ( < 2.0 [V] ):
STS A DOF X/U = -0.752 [V]
STS A DOF Y/V = -0.929 [V]
STS A DOF Z/W = -0.412 [V]
STS B DOF Y/V = -0.456 [V]
STS B DOF Z/W = -0.354 [V]
STS C DOF X/U = 0.42 [V]
STS C DOF Y/V = 0.846 [V]
STS C DOF Z/W = -0.161 [V]
STS EX DOF X/U = -0.057 [V]
STS EX DOF Y/V = 0.301 [V]
STS EX DOF Z/W = 0.226 [V]
STS EY DOF X/U = 0.524 [V]
STS EY DOF Y/V = -0.472 [V]
STS EY DOF Z/W = 0.735 [V]
There are 8 T240 proof masses out of range ( > 0.3 [V] )!
ETMX T240 2 DOF X/U = -1.296 [V]
ETMX T240 2 DOF Y/V = -1.309 [V]
ETMX T240 2 DOF Z/W = -0.865 [V]
ITMX T240 1 DOF X/U = -1.498 [V]
ITMX T240 3 DOF X/U = -1.545 [V]
ITMY T240 2 DOF Y/V = 0.305 [V]
ITMY T240 3 DOF X/U = -0.554 [V]
ITMY T240 3 DOF Z/W = -1.851 [V]
All other proof masses are within range ( < 0.3 [V] ):
ETMX T240 1 DOF X/U = -0.036 [V]
ETMX T240 1 DOF Y/V = -0.076 [V]
ETMX T240 1 DOF Z/W = -0.124 [V]
ETMX T240 3 DOF X/U = -0.112 [V]
ETMX T240 3 DOF Y/V = -0.135 [V]
ETMX T240 3 DOF Z/W = -0.092 [V]
ETMY T240 1 DOF X/U = -0.121 [V]
ETMY T240 1 DOF Y/V = 0.256 [V]
ETMY T240 1 DOF Z/W = -0.036 [V]
ETMY T240 2 DOF X/U = -0.053 [V]
ETMY T240 2 DOF Y/V = -0.076 [V]
ETMY T240 2 DOF Z/W = -0.085 [V]
ETMY T240 3 DOF X/U = -0.05 [V]
ETMY T240 3 DOF Y/V = -0.125 [V]
ETMY T240 3 DOF Z/W = 0.092 [V]
ITMX T240 1 DOF Y/V = 0.112 [V]
ITMX T240 1 DOF Z/W = 0.114 [V]
ITMX T240 2 DOF X/U = 0.09 [V]
ITMX T240 2 DOF Y/V = 0.173 [V]
ITMX T240 2 DOF Z/W = 0.165 [V]
ITMX T240 3 DOF Y/V = 0.061 [V]
ITMX T240 3 DOF Z/W = -0.047 [V]
ITMY T240 1 DOF X/U = 0.132 [V]
ITMY T240 1 DOF Y/V = 0.14 [V]
ITMY T240 1 DOF Z/W = 0.219 [V]
ITMY T240 2 DOF X/U = 0.093 [V]
ITMY T240 2 DOF Z/W = 0.211 [V]
ITMY T240 3 DOF Y/V = 0.182 [V]
BS T240 1 DOF X/U = -0.025 [V]
BS T240 1 DOF Y/V = -0.12 [V]
BS T240 1 DOF Z/W = 0.27 [V]
BS T240 2 DOF X/U = 0.077 [V]
BS T240 2 DOF Y/V = 0.242 [V]
BS T240 2 DOF Z/W = -0.027 [V]
BS T240 3 DOF X/U = 0.058 [V]
BS T240 3 DOF Y/V = -0.183 [V]
BS T240 3 DOF Z/W = -0.192 [V]
Hugh and I recentered all of these.
Reminder to future recenterers: Make sure that the chambers are in DAMPED, sensor correction is off, and Earthquake automation is OFF