Displaying report 1-1 of 1.
Reports until 00:05, Monday 09 March 2020
LHO General
patrick.thomas@LIGO.ORG - posted 00:05, Monday 09 March 2020 (55504)
Ops Eve Shift Summary
TITLE: 03/08 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Lock Acquisition
INCOMING OPERATOR: TJ
SHIFT SUMMARY: The IFO is relocking after a lock loss from an earthquake in Canada.
LOG:

23:48 UTC Cycled squeezer guardian due to increase in H1:SQZ-OPO_REFL_DC_POWER.
03:01 UTC Lock loss to earthquake in Canada. Lost lock just before the notification of the earthquake. Hit the big red button soon after. HAM4 ISI, OFI and ZM2 tripped.
03:35 UTC Hit RECOVER EQ.
03:36 UTC Started untripping WDs. I noticed the HAM5 ISI had a red 'Rogue Exc WD' button. I hit it and it turned green.
03:45 UTC Starting relocking.
04:51 UTC Back to observing. No SDF differences.
06:37 UTC Lock loss from earthquake in Canada. SEI_CONF is not letting me switch to EARTH_QUAKE.
06:46 UTC Relocking
Displaying report 1-1 of 1.