Since SEI_ENV is now the manager of SEI_CONF (alog55296), I made it a bit bigger on the ISI_CONFIG.adl screen.
Reminder to operators: On Tuesdays, make sure to take SEI_ENV to the MAINTENANCE state, otherwise it may jump to earthquake and turn on sensor correction during maintenance times. The MAINTENANCE state will turn off sensor correction so we won't have worry about it during that time.
I should note that this is reflected in our usual daily check sheet as well: https://lhocds.ligo-wa.caltech.edu/ops/opchecksheet