Camilla C, Sheila D, Jenne D, Jeff K
While investigating unknown locklosses, we have noticed spikes in DARM <1 second before we loose lock.
This has happened in 5 out of 24 unknown slower locklosses in Feb (
20% ). Similar spikes were seen in the 2 locklosses where the DARM offset was changed (
alog 55204).
We are suspicions that the OMC-DCPD's are saturating. I have attached images of the lockloss with the OMC-DCPD OUTPUT channels, the input channels are slow so don't currently have good data but it is important to note that the
filters applied reduce these ~100Hz features by a factor of 10
3!
Jenne captured the features on fast input channels from the higher DARM offset lockloss very close to saturating the DCPCs (saturates at value of+/-32768) although these features look small on the output channels (photo of
OUTPUT CHANNELS and
INPUT CHANNELS ). The other lockloss with higher DARM offset doesn't look as bad (
photo).
There is lots of examples of other locklosses with spikes before that I have attached:
here,
here,
here.
The bigger (~200,000 in ETMX_L3) spikes seem to occur without us loosing lock around 5-9 times a day. Not very often compared to how many times we loose lock just after seeing them!