Displaying report 1-1 of 1.
Reports until 10:00, Friday 13 March 2020
H1 SUS
sheila.dwyer@LIGO.ORG - posted 10:00, Friday 13 March 2020 (55583)
quad pum noisemon filters turned off

Sheila D, Chris W

While we were out of observing for other reasons, I turned off the pum noisemon filters which were calibrating the signals into DAC counts.  This was because Chris found that with the signals calibrated this way, we would need whitening to avoid digitization noise in the DQ channels.  Instead of doing that we are just removing the calibration filters.  

Accepted in SDF.  

Displaying report 1-1 of 1.