cheryl.vorvick@LIGO.ORG - posted 00:18, Sunday 15 March 2020 - last comment - 08:46, Monday 16 March 2020(55599)
OPS Eve Summary

TITLE: 03/15 Eve Shift: 23:00-07:00 UTC (16:00-00:00 PST), all times posted in UTC
STATE of H1: Observing at 114Mpc
INCOMING OPERATOR: Corey
SHIFT SUMMARY: Locked in Observe, range trending downward, no obvious reason
LOG:

Comments related to this report
sheila.dwyer@LIGO.ORG - 13:50, Sunday 15 March 2020 (55603)

After Rhaul loaded his change to the guardian code on Friday 55575, I expected that the guardian would no longer be setting gains to 0.  It looks like we have lost lock and relocked since the guardian change was loaded so it should have gone into place.  Did you find the gain set to 0?  

rahul.kumar@LIGO.ORG - 08:46, Monday 16 March 2020 (55614)

Here Guardian is setting it to max gain which is 0 for ITMY 12 (nominal is 1200).