Reports until 09:32, Monday 16 March 2020
H1 General (DetChar)
amber.stuver@LIGO.ORG - posted 09:32, Monday 16 March 2020 (55617)
DQ Shift Report (9-15 Mar 2020)
- 68.5% duty cycle with a consistent range between 115-118 Mpc, with the exception of ~ 85 Mpc between 08:30-12:20 on Friday.
- On Friday, the ETMY violin modes rung up to exceptional levels until lock loss, dropping the range, creating n*500 Hz glitches, and also low frequency scatter (as confirmed by hveto). This is due to the violin guardian begin turned off earlier in the day. This is all documented in aLog 55578 and responses.
- Earthquakes and wind were the causes of several lock losses.
- H1:LSC-POP_A_LF_OUT_DQ was a round winner every day of this shift and was effective at removing glitches from the "tail" (high SNR). Of all of the channels that picked up high SNR triggers, these triggers were usually extremely loud glitches. 

The complete DQ Shift documentation is available here.