J. Kissel I've gathered the full, regular calibration measurement suite today -- importantly -- *after* the OMC whitening chassis' filter configuration change (see LHO aLOG 55620). These measurements may end up being the reference measurements for a future calibration model parameter set. Data is committed here /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOSensingTFs/ 2020-03-16_H1_DARM_OLGTF_LF_SS_5to1100Hz_15min.xml 2020-03-16_H1_PCALY2DARMTF_LF_SS_5t1100Hz_10min.xml 2020-03-16_H1_PCALY2DARMTF_BB_3min.xml << Contains before (reference) and after (live) OMC whitening filter change. "Before change" measurement started at 2020-03-16 18:30:31 UTC, "after changes" started at 2020-03-16 18:35:14 UTC. /ligo/svncommon/CalSVN/aligocalibration/trunk/Runs/O3/H1/Measurements/FullIFOActuationTFs/ 2020-03-16_H1SUSETMX_L1_iEXC2DARM_8min.xml 2020-03-16_H1SUSETMX_L1_PCAL2DARM_5min.xml 2020-03-16_H1SUSETMX_L2_iEXC2DARM_12min.xml 2020-03-16_H1SUSETMX_L2_PCAL2DARM_6min.xml 2020-03-16_H1SUSETMX_L3_iEXC2DARM_12min.xml 2020-03-16_H1SUSETMX_L3_PCAL2DARM_6min.xml Analysis to come.