Reports until 10:04, Tuesday 17 March 2020
H1 CDS (SEI)
david.barker@LIGO.ORG - posted 10:04, Tuesday 17 March 2020 (55647)
Latest HEPI and HAM-ISI models installed

WP8554 senscor addition to HEPI and ISI models

Jim, Dave:

The SEI front end models were restarted in the following order:

2020_03_17 09:08 h1hpietmx
2020_03_17 09:08 h1hpietmy
2020_03_17 09:10 h1hpiham1
2020_03_17 09:10 h1hpiham2
2020_03_17 09:10 h1hpiham3
2020_03_17 09:10 h1isiham2
2020_03_17 09:11 h1hpiham4
2020_03_17 09:11 h1isiham3
2020_03_17 09:13 h1hpiham5
2020_03_17 09:13 h1hpiham6
2020_03_17 09:13 h1isiham4
2020_03_17 09:13 h1isiham5
2020_03_17 09:15 h1hpibs
2020_03_17 09:15 h1hpiitmy
2020_03_17 09:15 h1isiham6
2020_03_17 09:16 h1hpiitmx
In some cases the filter module file was slightly modified by a reordering of the header modules list (no actual filter change).

No DAQ restart was necessary.